RoofCalc.

Method and sources

A quantity is only useful if you can check it. These are all 23 rules behind the calculators, 17 of them from a published source and 6 of them our own arithmetic, with the reason for each.

How a rule is labelled

Every number in every calculator comes from one of two places. A rule tied to a published source carries the publisher, the document and the date we read it. A house rule is our own arithmetic, used where no one publishes a figure that would be true for every roof — a waste allowance, a downspout spacing, a roll arithmetic from standard dimensions — and it says why it exists.

There is no third category. If a number appears without a source and without a house-rule label, that is a bug, and the build is set up to fail when a rule is missing a basis.

What is derived, and what is quoted

Some of the most important numbers on this site are not quoted from anywhere; they are trigonometry. The pitch angle is the arctangent of rise over run. The multiplier is the square root of (rise squared plus 144) divided by 12. Rafter length is the run times the multiplier. Those are derived from the Pythagorean theorem and a scientific calculator, and they are reproducible: the pitch chart shows every value from 1:12 to 12:12 so you can check one against a framing square.

Everything else is quoted: three bundles per square, 25 ft of ridge per bundle, 1,000 sq ft per synthetic roll, 5,520 sq ft of gutter capacity, 12.5 sq in of net free area per foot of ridge vent. Those are manufacturer or code figures, and each one is linked below with the date it was read.

Roof pitch

RuleFormulaBasis
Pitch to angle Plain trigonometry, not a table. A 6:12 rise is 26.57 degrees because arctangent of 0.5 is 26.57. atan(rise ÷ 12) House rule
Rafter multiplier The multiplier turns horizontal run into slope length. 6:12 gives 1.118, 8:12 gives 1.202. √(12² + rise²) ÷ 12 Roof Observations (Jack Gray, RRO)
Shingle slope limit Below 2:12 the roof is outside what asphalt shingles may cover; from 2:12 to 4:12 the underlayment doubles. rise ≥ 2 in per 12 in International Code Council

Roof squares

RuleFormulaBasis
Footprint including eaves The roof runs past the wall on every side, so the overhang is added to both ends of both dimensions before the slope is applied. (length + 2h) × (width + 2h) House rule
Slope correction One square is 100 sq ft of sloped surface, so the footprint is corrected before dividing by 100. footprint × √(12² + rise²) ÷ 12 Roof Observations (Jack Gray, RRO)

Shingles

RuleFormulaBasis
Shingle bundles per square Standard for 3-tab and most architectural shingles. A few heavyweight products cover less per bundle; the label wins. 3 bundles × squares GAF
Ridge cap coverage Four bundles of GAF Seal-A-Ridge cover 100 lf, so one bundle covers about 25 lf at 6 2/3 in exposure. ridge lf ÷ 25 GAF
Starter strip coverage One bundle of GAF Pro-Start covers about 120.33 lf when the strips are split in half. eave and rake lf ÷ 120.33 GAF
Waste allowance No manufacturer publishes a waste figure because it depends on the roof plan. Ten percent covers a simple gable; hips and valleys consume more. 10% gable, 15% hip House rule

Underlayment

RuleFormulaBasis
Synthetic roll coverage GAF FeltBuster covers 10 squares per roll with laps excluded. 1,000 sq ft per roll GAF
Asphalt felt roll coverage Roll arithmetic from the standard 36 in roll widths. No single manufacturer publishes a felt coverage figure that covers every brand, so the roll dimensions are the basis. 36 in × 144 ft = 432 sq ft; 36 in × 72 ft = 216 sq ft House rule
Double layer below 4:12 From 2:12 up to 4:12 the code requires two layers, so the roll count doubles. The calculator does not double it automatically; check the slope first. × 2 below 4:12 International Code Council

Attic ventilation

RuleFormulaBasis
Net free area 1/150 of the vented floor area is the code baseline. The 1/300 exception needs a vapor retarder and climate zones 6 to 8. attic sq ft × 144 ÷ 150 International Code Council
Intake and exhaust split The code requires at least half the net free area at the upper vents; a 50/50 split is the usual design and stays inside the 40 to 50 percent upper band. 50% low, 50% high International Code Council
Ridge vent length Cobra RidgeRunner provides 12.5 sq in of net free area per linear foot. Other products differ, so the field is editable. exhaust sq in ÷ 12.5 GAF

Gutters and downspouts

RuleFormulaBasis
Gutter capacity Capacities are quoted at 1 in/hr of rainfall. A 6 in K-style raises the limit to 7,960 sq ft. 5 in K-style 5,520 sq ft This Old House
Downspout capacity A 2 × 3 in downspout handles about 600 sq ft, a 3 × 4 in about 1,200 sq ft, a 3 in round 706 sq ft and a 4 in round 1,255 sq ft. 3 × 4 in = 1,200 sq ft This Old House
Pitch factor Flat to 3:12 is 1.0, 4:12 to 5:12 is 1.05, 6:12 to 8:12 is 1.1, 9:12 to 11:12 is 1.2 and 12:12 or steeper is 1.3. 1.0 to 1.3 by pitch band This Old House
Downspout spacing No code publishes a spacing figure. Forty feet is the conservative end of common practice; the sizing guide itself says a 60 ft run needs an outlet at each end. one per 40 ft of run House rule

Sheathing

RuleFormulaBasis
Panel coverage APA-rated roof sheathing is commonly 4 × 8 ft. A 4 × 10 panel is 40 sq ft and is offered as an option. 4 × 8 ft = 32 sq ft APA – The Engineered Wood Association
Panel thickness A 7/16 in panel spans rafters at 24 in on center. Thinner panels need closer spacing or are not a roof deck. 7/16 in, 24/16 span rating APA – The Engineered Wood Association

Rafters

RuleFormulaBasis
Rafter length The run to the ridge is half the span; the overhang is horizontal, so it is added to the run before the multiplier is applied. (span ÷ 2 + overhang) × multiplier Roof Observations (Jack Gray, RRO)
Ridge height The same rise-per-foot arithmetic as the pitch: 15 ft of run at 6:12 rises 7.5 ft. run × rise ÷ 12 House rule

Where the data comes from

The list below is the complete set of sources, 11 of them, with the facts each one was used for. Every entry carries the date it was read: 20 November 2026.

Editorial rules

What this site does not do

Accuracy and corrections

The calculators are arithmetic on published coverage figures, so their accuracy depends on the inputs and on the product you actually bought. A bundle that covers 32 sq ft instead of 33.3 will change the order; so will a downspout with three elbows instead of one. Where a manufacturer's figure differs from the one used here, the product label wins, and the calculator's fields are editable so you can enter it.

If a number here disagrees with your supplier or your building official, the correction belongs in the rules file with a source and a date, and every calculator that uses it changes with it. That is the advantage of keeping the rules separate from the pages: one edit fixes the whole site.

How the pages are built

RoofCalc is a static site generated with Astro. Each calculator is a pure function: no network, no clock, no browser state. The same function produces the default result during the build and recalculates in the browser when you change a field, which is why the number in the static HTML and the number after you click are produced by the same code.

Before every build, a validation script checks that each source has a URL and a reading date, that each rule has a formula and a valid basis, that each calculator has a default for every field and that every default is inside its own minimum and maximum. After the build, a link check confirms that every internal link resolves and every indexable page is in the sitemap, and a word count confirms that no page is thin. If any of those fail, the build fails rather than publishing a broken page.

Advertising and independence

The site is supported by display advertising, which is disclosed on the privacy page. Advertisers do not see the numbers you enter, because the calculators never send them anywhere. No advertiser, supplier or contractor has any influence over the formulas, the sources or the order of the results.