Method and sources
A quantity is only useful if you can check it. These are all 23 rules behind the calculators, 17 of them from a published source and 6 of them our own arithmetic, with the reason for each.
How a rule is labelled
Every number in every calculator comes from one of two places. A rule tied to a published source carries the publisher, the document and the date we read it. A house rule is our own arithmetic, used where no one publishes a figure that would be true for every roof — a waste allowance, a downspout spacing, a roll arithmetic from standard dimensions — and it says why it exists.
There is no third category. If a number appears without a source and without a house-rule label, that is a bug, and the build is set up to fail when a rule is missing a basis.
What is derived, and what is quoted
Some of the most important numbers on this site are not quoted from anywhere; they are trigonometry. The pitch angle is the arctangent of rise over run. The multiplier is the square root of (rise squared plus 144) divided by 12. Rafter length is the run times the multiplier. Those are derived from the Pythagorean theorem and a scientific calculator, and they are reproducible: the pitch chart shows every value from 1:12 to 12:12 so you can check one against a framing square.
Everything else is quoted: three bundles per square, 25 ft of ridge per bundle, 1,000 sq ft per synthetic roll, 5,520 sq ft of gutter capacity, 12.5 sq in of net free area per foot of ridge vent. Those are manufacturer or code figures, and each one is linked below with the date it was read.
Roof pitch
| Rule | Formula | Basis |
|---|---|---|
| Pitch to angle Plain trigonometry, not a table. A 6:12 rise is 26.57 degrees because arctangent of 0.5 is 26.57. | atan(rise ÷ 12) | House rule |
| Rafter multiplier The multiplier turns horizontal run into slope length. 6:12 gives 1.118, 8:12 gives 1.202. | √(12² + rise²) ÷ 12 | Roof Observations (Jack Gray, RRO) |
| Shingle slope limit Below 2:12 the roof is outside what asphalt shingles may cover; from 2:12 to 4:12 the underlayment doubles. | rise ≥ 2 in per 12 in | International Code Council |
Roof squares
| Rule | Formula | Basis |
|---|---|---|
| Footprint including eaves The roof runs past the wall on every side, so the overhang is added to both ends of both dimensions before the slope is applied. | (length + 2h) × (width + 2h) | House rule |
| Slope correction One square is 100 sq ft of sloped surface, so the footprint is corrected before dividing by 100. | footprint × √(12² + rise²) ÷ 12 | Roof Observations (Jack Gray, RRO) |
Shingles
| Rule | Formula | Basis |
|---|---|---|
| Shingle bundles per square Standard for 3-tab and most architectural shingles. A few heavyweight products cover less per bundle; the label wins. | 3 bundles × squares | GAF |
| Ridge cap coverage Four bundles of GAF Seal-A-Ridge cover 100 lf, so one bundle covers about 25 lf at 6 2/3 in exposure. | ridge lf ÷ 25 | GAF |
| Starter strip coverage One bundle of GAF Pro-Start covers about 120.33 lf when the strips are split in half. | eave and rake lf ÷ 120.33 | GAF |
| Waste allowance No manufacturer publishes a waste figure because it depends on the roof plan. Ten percent covers a simple gable; hips and valleys consume more. | 10% gable, 15% hip | House rule |
Underlayment
| Rule | Formula | Basis |
|---|---|---|
| Synthetic roll coverage GAF FeltBuster covers 10 squares per roll with laps excluded. | 1,000 sq ft per roll | GAF |
| Asphalt felt roll coverage Roll arithmetic from the standard 36 in roll widths. No single manufacturer publishes a felt coverage figure that covers every brand, so the roll dimensions are the basis. | 36 in × 144 ft = 432 sq ft; 36 in × 72 ft = 216 sq ft | House rule |
| Double layer below 4:12 From 2:12 up to 4:12 the code requires two layers, so the roll count doubles. The calculator does not double it automatically; check the slope first. | × 2 below 4:12 | International Code Council |
Attic ventilation
| Rule | Formula | Basis |
|---|---|---|
| Net free area 1/150 of the vented floor area is the code baseline. The 1/300 exception needs a vapor retarder and climate zones 6 to 8. | attic sq ft × 144 ÷ 150 | International Code Council |
| Intake and exhaust split The code requires at least half the net free area at the upper vents; a 50/50 split is the usual design and stays inside the 40 to 50 percent upper band. | 50% low, 50% high | International Code Council |
| Ridge vent length Cobra RidgeRunner provides 12.5 sq in of net free area per linear foot. Other products differ, so the field is editable. | exhaust sq in ÷ 12.5 | GAF |
Gutters and downspouts
| Rule | Formula | Basis |
|---|---|---|
| Gutter capacity Capacities are quoted at 1 in/hr of rainfall. A 6 in K-style raises the limit to 7,960 sq ft. | 5 in K-style 5,520 sq ft | This Old House |
| Downspout capacity A 2 × 3 in downspout handles about 600 sq ft, a 3 × 4 in about 1,200 sq ft, a 3 in round 706 sq ft and a 4 in round 1,255 sq ft. | 3 × 4 in = 1,200 sq ft | This Old House |
| Pitch factor Flat to 3:12 is 1.0, 4:12 to 5:12 is 1.05, 6:12 to 8:12 is 1.1, 9:12 to 11:12 is 1.2 and 12:12 or steeper is 1.3. | 1.0 to 1.3 by pitch band | This Old House |
| Downspout spacing No code publishes a spacing figure. Forty feet is the conservative end of common practice; the sizing guide itself says a 60 ft run needs an outlet at each end. | one per 40 ft of run | House rule |
Sheathing
| Rule | Formula | Basis |
|---|---|---|
| Panel coverage APA-rated roof sheathing is commonly 4 × 8 ft. A 4 × 10 panel is 40 sq ft and is offered as an option. | 4 × 8 ft = 32 sq ft | APA – The Engineered Wood Association |
| Panel thickness A 7/16 in panel spans rafters at 24 in on center. Thinner panels need closer spacing or are not a roof deck. | 7/16 in, 24/16 span rating | APA – The Engineered Wood Association |
Rafters
| Rule | Formula | Basis |
|---|---|---|
| Rafter length The run to the ridge is half the span; the overhang is horizontal, so it is added to the run before the multiplier is applied. | (span ÷ 2 + overhang) × multiplier | Roof Observations (Jack Gray, RRO) |
| Ridge height The same rise-per-foot arithmetic as the pitch: 15 ft of run at 6:12 rises 7.5 ft. | run × rise ÷ 12 | House rule |
Where the data comes from
The list below is the complete set of sources, 11 of them, with the facts each one was used for. Every entry carries the date it was read: 20 November 2026.
- How Many Bundles of Shingles Are in a Square? — GAF, read Nov 20, 2026
- Three bundles of standard 3-tab or architectural asphalt shingles cover one square.
- One roofing square is 100 sq ft of roof surface, or a 10 × 10 ft area.
- Minimum Slope for Shingles: What Contractors Need to Know — GAF, read Nov 20, 2026
- The minimum slope for asphalt shingles is 2:12.
- A roof from 2:12 up to but not including 4:12 is treated as low slope and needs a double layer of underlayment.
- Seal-A-Ridge Ridge Cap Shingles sell sheet (RESHR112) — GAF, read Nov 20, 2026
- Four bundles of Seal-A-Ridge cover 100 linear feet of ridge, about 25 linear feet per bundle.
- Each bundle holds 45 ridge caps at a 6 2/3 in exposure.
- Pro-Start Starter Strip Shingles sell sheet (RESGN546) — GAF, read Nov 20, 2026
- One bundle of Pro-Start covers approximately 120.33 linear feet when the strips are split in half.
- A bundle contains 19 full sheets, or 38 individual pieces.
- FeltBuster Synthetic Roofing Felt sell sheet (RESUL183) — GAF, read Nov 20, 2026
- One roll covers 10 squares, or 1,000 sq ft, with laps excluded.
- The roll is 48 in wide, 250 ft long and weighs about 23 lb.
- Cobra RidgeRunner Roof Ridge Vent — GAF, read Nov 20, 2026
- Cobra RidgeRunner provides 12.5 sq in of net free ventilating area per linear foot.
- GAF recommends at least 1 sq ft of net free ventilation for every 300 sq ft of attic floor space as a minimum.
- 2021 International Residential Code, R806.2 Minimum vent area — International Code Council, read Nov 20, 2026
- The minimum net free ventilating area is 1/150 of the area of the vented space.
- At least 50 percent of the required area is provided by ventilators in the upper portion of the space, with the balance at the eaves.
- A reduced 1/300 ratio is allowed only where the code exception applies: a Class I or II vapor retarder in climate zones 6 to 8 and 40 to 50 percent of the vent area at the upper vents.
- 2021 International Residential Code, R905.2.2 Slope — International Code Council, read Nov 20, 2026
- Asphalt shingles are permitted only on roof slopes of 2:12 (17 percent) or greater.
- From 2:12 up to 4:12, double underlayment is required under asphalt shingles.
- APA Panel Roof Sheathing (Engineered Wood Construction Guide excerpt) — APA – The Engineered Wood Association, read Nov 20, 2026
- Roof sheathing panels are commonly 4 × 8 ft, which is 32 sq ft per panel.
- A 7/16 in panel carries a 24/16 span rating, for rafter spacing up to 24 in on center.
- Panel edges and ends are spaced about 1/8 in apart at installation.
- How To Size Gutters and Downspouts — This Old House, read Nov 20, 2026
- A 5 in K-style gutter handles up to 5,520 sq ft of drainage area at a 1 in/hr rainfall rate; a 6 in K-style handles 7,960 sq ft.
- A 2 × 3 in rectangular downspout handles about 600 sq ft; a 3 × 4 in downspout about 1,200 sq ft.
- A 3 in round downspout handles about 706 sq ft; a 4 in round downspout about 1,255 sq ft.
- Gutters are pitched about 1/4 in per 10 ft, and a run of 60 ft or more should have an outlet at each end.
- Roof pitch factors run from 1.0 for flat to 3:12 up to 1.3 for 12:12 and steeper.
- Roof Pitch Multiplier: Calculator, Table & Guide — Roof Observations (Jack Gray, RRO), read Nov 20, 2026
- The multiplier is the square root of ((rise ÷ run)² + 1), with a run of 12.
- A 6:12 roof has a multiplier of 1.118 and an angle of 26.57 degrees.
- Multiplying the horizontal run by the multiplier gives the rafter length.
Editorial rules
- A number appears with a source and a date, or it is labelled a house rule with the reason. No exceptions.
- Ranges are shown, not hidden. Where one maker's ridge vents run from 12.5 to 18 sq in of net free area per foot, the calculator lets you enter the product's own figure instead of picking one for you.
- When a source changes, the rule changes and the reading date on the source list changes with it.
- The calculators run in your browser. Nothing you enter is transmitted, stored or attached to an identifier.
- Advertising never changes a recommendation. There are no affiliate links and no sponsored material on this site.
- Every calculator page shows its default result in the static HTML, so the method can be read and checked without running any script.
What this site does not do
- No prices. Roofing cost depends on the region, the access, the tear-off, the season and the contractor. A national dollar figure would be invented, so this site publishes quantities only.
- No structural design. Rafter size, sheathing thickness and ridge support come from span tables and an engineer, not from a geometry calculator.
- No local code interpretation. Snow loads, wind zones, permit thresholds and historic-district rules are set locally. The IRC figures here are the baseline, and your building department is the authority.
- No warranty advice. Manufacturer warranties have conditions about ventilation, underlayment and installation that a calculator cannot check.
- No market data. This is not a lead-generation site; there is no form, no account and no quote request.
Accuracy and corrections
The calculators are arithmetic on published coverage figures, so their accuracy depends on the inputs and on the product you actually bought. A bundle that covers 32 sq ft instead of 33.3 will change the order; so will a downspout with three elbows instead of one. Where a manufacturer's figure differs from the one used here, the product label wins, and the calculator's fields are editable so you can enter it.
If a number here disagrees with your supplier or your building official, the correction belongs in the rules file with a source and a date, and every calculator that uses it changes with it. That is the advantage of keeping the rules separate from the pages: one edit fixes the whole site.
How the pages are built
RoofCalc is a static site generated with Astro. Each calculator is a pure function: no network, no clock, no browser state. The same function produces the default result during the build and recalculates in the browser when you change a field, which is why the number in the static HTML and the number after you click are produced by the same code.
Before every build, a validation script checks that each source has a URL and a reading date, that each rule has a formula and a valid basis, that each calculator has a default for every field and that every default is inside its own minimum and maximum. After the build, a link check confirms that every internal link resolves and every indexable page is in the sitemap, and a word count confirms that no page is thin. If any of those fail, the build fails rather than publishing a broken page.
Advertising and independence