Underlayment calculator
Rolls of synthetic membrane or asphalt felt for the roof area you have, with the roll size you actually bought and the laps already accounted for.
Default scenario: 15 squares, synthetic underlayment at 1,000 sq ft per roll, 10% waste. Change a field and recalculate for your roof.
Your result
2 rolls
Synthetic underlayment at 1,000 sq ft per roll, covering 1,650 sq ft with 10% waste
| Roof area to cover | 15 squares | 1,650 sq ft including waste |
| Coverage per roll | 1,000 sq ft | GAF FeltBuster: 10 squares (1,000 sq ft) per roll, laps excluded |
| Rolls needed | 2 | Rounded up to whole rolls |
- Published roll coverage already includes the standard side and end laps, so the waste allowance here only covers cuts and corners.
- Rolls are whole units: 1.65 rolls of coverage becomes 2 rolls to buy.
Before you buy
- Underlayment laps must run over the lower course, never under it: water travels down the slope.
- Ice-dam membrane is a separate product at the eaves in cold climates (IRC R905.1.2); it is not counted here.
Other options
- #15 felt — 4 rolls at 432 sq ft each — cheaper per square, but heavier and less tear-resistant.
What underlayment is for
Underlayment is the layer between the roof deck and the shingles. It is not a spare roof; it is a secondary drainage plane that takes over where wind-driven rain gets past a shingle joint, and it protects the deck while the roof is open. It also keeps the shingles from sticking to the deck, which matters when the roof is later torn off.
Because it covers the whole deck, its quantity is driven by the same square count as the shingles, with one extra variable: what the roll covers. That number is printed on the roll and varies more than people expect.
Roll coverage by material
| Material | Roll size | Coverage |
|---|---|---|
| Synthetic underlayment | 48 in × 250 ft | 1,000 sq ft, 10 squares (GAF FeltBuster) |
| #15 asphalt felt | 36 in × 144 ft | About 432 sq ft, 4.3 squares |
| #30 asphalt felt | 36 in × 72 ft | About 216 sq ft, 2.2 squares |
The synthetic roll is 48 in wide and 250 ft long, which is 1,000 sq ft of membrane before laps. GAF's own data sheet says the coverage excludes laps, so a 10% allowance is not padding; it is the overlap the installation needs. Felt rolls are narrower and shorter, and the coverage figures above come from the roll dimensions rather than from a single manufacturer's claim. That distinction is recorded on the method page.
Why synthetic has mostly replaced felt
A 1,000 sq ft synthetic roll weighs about 23 lb, so one person can carry a whole roof's worth. Covering the same area in #15 felt takes about 2.3 rolls, and felt tears when it is walked on, wrinkles when it gets wet and breaks down in UV within weeks. On a roof that will be open for a weekend, felt is fine. On a roof that might be open for a month, synthetic is the safer choice.
The trade is cost per square and slipperiness. Synthetic membrane is slicker underfoot than felt, especially with morning dew, and it needs to be stapled or capped-nailed according to the manufacturer's pattern rather than nailed through the middle of the sheet.
Laps, direction and the 2:12 rule
Underlayment laps must run over the lower course, never under it. Water travels down the slope, so the upper sheet overlaps the lower one by at least 2 in at the side and 4 in at the end on a conventional roof. On a low-slope roof the laps get wider, which is one reason the coverage falls.
From 2:12 up to 4:12 the code requires two layers of underlayment under asphalt shingles (IRC R905.2.2). This calculator does not double the roll count automatically, because the slope is not one of its inputs; if your pitch is under 4:12, multiply the roll count by two. That is the single most expensive omission on a low-slope shingle roof.
Where ice-dam membrane goes
Ice-dam membrane is a self-adhering rubberized sheet that goes under the underlayment at the eaves, in valleys and around penetrations. IRC R905.1.2 requires it in areas where the average January temperature is 25°F or lower, and good practice puts it there in most cold climates regardless. It is bought by the linear foot or by the square and is not part of this roll count.
The membrane goes down first, directly on the deck, and the underlayment laps over it. Putting it on top of the underlayment defeats the purpose, because water then has to cross the membrane to reach the drain path.
Underlayment is not a vapor barrier
A common confusion: underlayment sheds water that gets past the shingles, but it is not a vapor retarder for the house. Vapor moves through the ceiling assembly and is controlled on the warm side of the insulation. Sealing the roof deck with a vapor-tight membrane can trap moisture in the deck, which is why some codes and manufacturers want a vapor-permeable underlayment over a ventilated attic. Ask before substituting a product with a low perm rating.
Working out the rolls yourself
Multiply the squares by 100 to get square feet, add the waste percentage, then divide by the roll coverage and round up. For 15 squares of synthetic at 10% waste: 15 × 100 = 1,500 sq ft, × 1.10 = 1,650 sq ft, ÷ 1,000 = 1.65, so two rolls.
For the same roof in #15 felt: 1,650 ÷ 432 = 3.82, so four rolls. The felt is cheaper per roll and needs twice as many rolls, which is why the per-square comparison never matches the per-roll price on the shelf.
What this calculator leaves out
- Ice-dam membrane at the eaves and in valleys. Separate product, separate count.
- Double layers below 4:12. Multiply the result by two.
- Drip edge and valley metal. Sheet metal by the linear foot.
- Staples and cap nails. A box covers roughly 10 to 16 squares depending on the pattern.
- Ridge vent. It replaces underlayment at the ridge on many installations; check the vent instructions.
Frequently asked
How many rolls of synthetic underlayment for 15 squares?
Two rolls. A roll covers 10 squares, and 15 squares plus 10% waste is 16.5 squares, so one roll is short.
How many square feet are in a roll of 15 lb felt?
About 432 sq ft on a standard 36 in × 144 ft roll, or roughly four squares. A #30 roll is the same width and half the length, about 216 sq ft.
Does underlayment coverage include laps?
The manufacturer’s figure usually does, but GAF states its 1,000 sq ft synthetic coverage excludes laps. That is why a 10% waste allowance is sensible even on a simple roof.
Do I need two layers under shingles?
From 2:12 up to 4:12, yes: IRC R905.2.2 requires double underlayment. At 4:12 and above, one layer is the normal installation.
Is underlayment the same as ice and water shield?
No. Underlayment covers the whole deck; ice-dam membrane is a self-adhering strip at the eaves, valleys and penetrations. It is a separate product with its own roll count.
Where these numbers come from
- FeltBuster Synthetic Roofing Felt sell sheet (RESUL183) — GAF, read Nov 20, 2026
- 2021 International Residential Code, R905.2.2 Slope — International Code Council, read Nov 20, 2026
- Minimum Slope for Shingles: What Contractors Need to Know — GAF, read Nov 20, 2026
Figures that come from our own arithmetic rather than a published table are marked house rule on the method page. No price is shown anywhere on this site because no supplier publishes one national figure that would be true for your town and your roof.
Related: shingle bundles · roof squares · deck panels · roof pitch