RoofCalc.

Gutter and downspout calculator

Two questions, one answer: is this gutter big enough for the roof, and how many downspouts does the run need to keep up with the pitch.

Default scenario: 40 × 30 ft roof at 6:12, 5 in K-style gutter, 3 × 4 in downspouts. Change a field and recalculate for your roof.

Your result

4 downspouts

140 ft of 5 in K-style gutter, design drainage area 1,320 sq ft

Roof footprint 1,200 sq ft 40 × 30 ft plan area
Pitch factor 1.10 Steeper roofs shed faster; 6:12 uses 1.10
Design drainage area 1,320 sq ft Footprint × pitch factor
Gutter capacity 5,520 sq ft 5 in K-style, per manufacturer sizing table
Each downspout handles 1,200 sq ft 3 × 4 in rectangular
Downspouts by capacity 2 ceiling(1,320 ÷ 1,200)
Downspouts by spacing 4 140 ft of run ÷ 40 ft (house rule)
Gutter length 140 ft Perimeter of the footprint
  • Gutter capacity is quoted at a 1 in/hr rainfall rate; your local design storm may be higher, which is why the spacing rule is checked separately.
  • The pitch factor grows the drainage area because a steep roof delivers water to the gutter faster than a flat one.

Before you buy

  • Hang the gutter with about 1/4 in of fall per 10 ft toward the downspout (This Old House sizing guide).
  • A run of 60 ft or more wants an outlet at each end, with the gutter pitched to both.
  • Discharge at least 4 to 6 ft from the foundation, and never into a footing drain you cannot inspect.

Other options

  • 6 in K-style — More headroom for valleys and long runs, at a higher material cost.

Gutter sizing is a drainage-area problem

A gutter does not fail because it is the wrong colour. It fails because the roof above it delivers more water than the gutter and its downspouts can carry, and the water goes over the front edge. The published capacity of a gutter is quoted as square feet of roof drainage area at a rainfall rate of 1 in/hr, so the job is to work out the drainage area, adjust it for pitch, and compare it with the capacity of the profile you want.

ProfileCapacityTypical use
5 in K-style5,520 sq ftMost houses
6 in K-style7,960 sq ftLarge or steep roofs, long runs
5 in half-round2,500 sq ftSmall roof sections, period houses
6 in half-round3,840 sq ftLarger period houses

The gap between K-style and half-round surprises people. A half-round gutter carries less water at the same nominal width because the open top is narrower for its depth. A 5 in half-round is roughly half the capacity of a 5 in K-style.

The pitch factor

A steep roof delivers water to the gutter faster than a flat one, so the sizing tables multiply the plan area by a pitch factor. This Old House publishes 1.0 for flat to 3:12, 1.05 for 4:12 to 5:12, 1.1 for 6:12 to 8:12, 1.2 for 9:12 to 11:12, and 1.3 for 12:12 and steeper.

At 6:12 a 40 × 30 ft roof has 1,200 sq ft of plan area and a design load of 1,320 sq ft. That is still well inside a 5 in K-style gutter's 5,520 sq ft, which is why most houses can use the standard profile. The pitch factor matters on big roofs and on long runs, where the margin is thinner.

Downspouts are the bottleneck

A gutter full of water with nowhere to drain is a bathtub. Downspout capacity is quoted the same way as gutter capacity, in square feet of roof area: about 600 sq ft for a 2 × 3 in rectangular downspout, 1,200 sq ft for a 3 × 4 in, 706 sq ft for a 3 in round and 1,255 sq ft for a 4 in round.

Those figures are for a vertical drop with a short offset. Every bend, every elbow and every long horizontal run reduces the real capacity. A downspout that crosses a porch roof on the way down is not a 1,200 sq ft downspout.

Why this calculator checks two rules

Capacity alone is not enough. A single 3 × 4 in downspout might handle the water volume on a 140 ft run, but the gutter would still overflow at the far end because the water has to travel 70 ft to get there. So the calculator takes the larger of two numbers: the count needed by capacity, and the count needed by spacing.

The spacing rule here is one downspout per 40 ft of run, which is a conservative working figure rather than a code number; it is marked as a house rule on the method page. The sizing guide itself says a run of 60 ft or more should have an outlet at each end, which is a stronger version of the same idea.

Where the water actually concentrates

A valley can deliver several roof planes to one point on the gutter. That point may need its own outlet even when the total roof area is small. The same is true of a roof that steps down onto a lower roof: the lower gutter receives the upper roof's water plus its own.

If you have valleys, count the roof planes that drain into each gutter run and use that area, not the whole house. This calculator assumes one simple rectangle; for a complex roof, run it once per drainage area and add the downspouts.

Slope, hangers and the fascia

Gutters are hung with about 1/4 in of fall per 10 ft. On a 40 ft run that is 1 in of drop from one end to the other, which is enough to move water and not enough to see from the street. Hangers go into the fascia or the rafter tails, never into the soffit alone; a gutter full of water is heavy, and a soffit is not structural.

The gutter must also sit below the roof plane so that water running off the shingles lands inside it, and the drip edge should overhang the gutter by an inch or so rather than dumping water behind it.

Discharge and the foundation

The best-sized gutter fails if the downspout discharges at the foundation. Aim for 4 to 6 ft of horizontal distance, or a buried line that daylights downhill. Splash blocks help but they do not replace slope away from the house, and a downspout that empties into a window well is a basement leak waiting for a storm.

In cold climates, the downspout should not be connected to a footing drain you cannot inspect. Ice and debris block it, and the water backs up into the basement.

What this calculator does not do

A worked example

A 40 × 30 ft roof at 6:12 has 1,200 sq ft of plan area. The 6:12 band uses a 1.1 factor, so the design load is 1,320 sq ft. A 5 in K-style gutter handles 5,520 sq ft, so it is comfortably adequate. A 3 × 4 in downspout handles 1,200 sq ft, so capacity alone calls for two downspouts. The perimeter is 140 ft, and at one per 40 ft that is four. The answer is four downspouts, and the gutter profile is not the constraint.

Frequently asked

How many downspouts does a 1,200 sq ft roof need?

With 3 × 4 in downspouts, two by capacity: 1,200 sq ft at a 6:12 pitch is a design load of about 1,320 sq ft, and each downspout handles 1,200. Spacing usually pushes it to four on a 140 ft perimeter.

How much roof area can a 5 inch gutter handle?

About 5,520 sq ft at a 1 in/hr rainfall rate, according to the sizing table published by This Old House. A 6 inch K-style gutter raises it to 7,960 sq ft.

How far apart should downspouts be?

One per 40 ft of gutter run is a conservative working rule, and a run of 60 ft or more should have an outlet at each end. Local rainfall intensity can require more.

What slope should a gutter have?

About 1/4 in of fall per 10 ft toward the downspout. Less than that and water stands; more and the gutter line becomes visible against the fascia.

Do gutter guards increase capacity?

No. Guards keep debris out but reduce the open area, and they cannot make a 5 in gutter handle a 6 in job. Size the gutter first, then decide on guards.

Where these numbers come from

Figures that come from our own arithmetic rather than a published table are marked house rule on the method page. No price is shown anywhere on this site because no supplier publishes one national figure that would be true for your town and your roof.

Related: roof squares · roof pitch · sheathing · sources and house rules