Turn the rise you measured into the three numbers a roofer actually uses: the pitch ratio, the angle in degrees and the multiplier that converts a flat run into slope length.

Default scenario: 6 in of rise per 12 in of run, checked over a 12 ft run. Change a field and recalculate for your roof.

Your result

6:12 pitch

26.6° · 50% slope · 1.118 multiplier

Pitch 6:12 Inches of rise per 12 in of horizontal run
Angle 26.6° arctan(rise ÷ 12)
Slope 50% (rise ÷ 12) × 100
Rafter multiplier 1.118 √(12² + rise²) ÷ 12
Rise over 12 ft of run 6 ft 0 in Horizontal run × rise ÷ 12
Rafter length for that run 13 ft 5 in Horizontal run × multiplier
Classification Conventional, 4:12 to under 8:12 Based on IRC slope limits for asphalt shingles
  • The angle is arctan(6 ÷ 12) = 26.57°.
  • The multiplier is √(144 + 6²) ÷ 12 = 1.118, so every 1 ft of run becomes 1.118 ft of rafter.

What roof pitch actually measures

Roof pitch is a ratio, not an angle: the number of inches the roof rises for every 12 inches it runs horizontally. A 6:12 roof goes up 6 in while it goes across 12 in. That is why the number is written with a colon or as "6 in 12" and why 6/12, 6:12 and "six-twelve" all mean the same roof.

Slope percentage and degrees describe the same triangle in different units. Percentage is rise divided by run times 100, so 6:12 is 50%. Degrees are the arctangent of rise divided by run, so 6:12 is 26.57°. A 45° roof is 12:12, which is 100% slope. Mixing the three up is the most common estimating error on a roof, and it is a expensive one: a roofer who orders for 26% instead of 26° is planning a much flatter roof than the one on the house.

The multiplier, and why it is the useful number

The pitch multiplier is the length of the slope divided by the length of the run. For a rise measured in inches per 12 in of run, it is √(12² + rise²) ÷ 12. At 6:12 that is √180 ÷ 12 = 1.118. Every horizontal foot of run becomes 1.118 ft of rafter or roof surface.

Three quantities come straight out of it. Roof surface is the footprint times the multiplier, which is how the roof square calculator gets from a plan area to squares. Rafter length is the run times the multiplier, which is what the rafter calculator does. And the ridge height is the run times the rise divided by 12, no multiplier needed.

The multiplier only works on the run, never on a measurement taken along the slope. If you measure a rafter with a tape, you already have the slope length and must not multiply it again. That double count is the other classic mistake, and it can inflate a shingle order by 10 to 25%.

Pitch bands that change what you can install

Slope is not just a shape; it decides which roof coverings are allowed and how they must be installed.

PitchAngleWhat it means
Under 2:12Under 9.5°Low slope. No asphalt shingles; membrane or metal only.
2:12 to under 4:129.5° to 18.4°Shingles allowed with double underlayment (IRC R905.2.2).
4:12 to under 8:1218.4° to 33.7°Conventional roof. Standard shingle installation, walkable with care.
8:12 and up33.7° and upSteep. Roof jacks, staging and fall protection become normal.

The 2:12 and 4:12 lines are code, not custom: the International Residential Code limits asphalt shingles to 2:12 and above and requires a second layer of underlayment below 4:12. GAF's own guidance describes 2:12 to 4:12 as low slope for exactly this reason. Below 2:12, water moves slowly enough that shingle laps cannot keep it out, so the roof needs a continuous membrane.

How to measure the pitch you have

  1. On a gable end. Hold a 24 in level horizontally against the rake trim. Measure from the far end of the level straight down to the roof edge. That drop, divided by 24 and multiplied by 12, is the rise.
  2. At a rafter tail. From a ladder at the eave, set the level against the underside of a rafter and measure the drop over 12 in. This reads the same pitch as the roof surface.
  3. From the attic. Measure the rise of a rafter over a known horizontal distance at the ridge; the geometry is identical and it is a lot safer.
  4. From total dimensions. If you know the building width and the ridge height above the wall plate, rise per foot of run is ridge height ÷ half the span, and pitch is that times 12.

A phone angle finder is fine for a sanity check but not for ordering material. The sensor is usually accurate to about a degree, which is roughly a quarter of a unit of pitch, and the case can sit off the roof surface.

Pitch, snow and rain

Steeper roofs shed water and snow faster, which is why cold-climate houses often run 8:12 to 12:12. But steeper roofs also present more surface to wind-driven rain and need more material, more staging and more careful flashing at valleys and sidewalls. A 4:12 roof in Vermont is not automatically wrong, but it will hold snow longer and needs ice-dam protection at the eaves.

Wind is the opposite pressure. Above about 8:12, shingle tabs catch more wind at the rake and ridge, so the perimeter nailing pattern and the ridge cap matter more than the field. That is a reason to follow the manufacturer's high-wind detail rather than to avoid the pitch.

What this calculator does not tell you

A worked example

You measure 6 in of drop over a 12 in run. The calculator returns 6:12, 26.57°, 50% and 1.118. A 40 × 30 ft house with 1 ft eaves has a footprint of 42 × 32 = 1,344 sq ft, so its roof surface is 1,344 × 1.118 = 1,503 sq ft, or 15.03 squares. At 3 bundles per square and 10% waste that is 50 bundles of field shingles, before ridge cap and starter strip. The shingle calculator carries those numbers through to a purchase count.

Frequently asked

What is a 6:12 roof pitch in degrees?

A 6:12 roof rises 6 in for every 12 in of run. That is 26.57 degrees, a 50% slope, and a rafter multiplier of 1.118. The angle is arctangent of 6 ÷ 12.

How do I measure roof pitch without climbing the roof?

Hold a 24 in level against the gable trim or a rafter tail so it is perfectly horizontal, then measure from the end of the level down to the roof surface. Divide that drop by 24 and multiply by 12. From the ground, sight along the gable edge and compare total rise to total run.

What is the minimum pitch for asphalt shingles?

Two units of rise per 12 of run. IRC R905.2.2 permits asphalt shingles at 2:12 and above, and requires double underlayment from 2:12 up to 4:12. Below 2:12 the roof needs a membrane or metal.

Is a 4:12 roof the same as 18 degrees?

Not quite: 4:12 is 18.43 degrees. Roofers often say "18 degrees" as shorthand, but the difference matters when you buy a pitch finder or set a saw.

Does roof pitch change how many shingles I need?

Yes. A 4:12 roof has a multiplier of 1.054 and an 8:12 roof 1.202, so the same footprint carries about 14% more roof surface at 8:12. That is a full square on a 15-square roof.

Where these numbers come from

Figures that come from our own arithmetic rather than a published table are marked house rule on the method page. No price is shown anywhere on this site because no supplier publishes one national figure that would be true for your town and your roof.